{"id":12119,"date":"2026-08-16T19:35:49","date_gmt":"2026-08-16T19:35:49","guid":{"rendered":"https:\/\/devpan.com\/jeux-de-barres-cuivre-ou-aluminium\/"},"modified":"2026-09-19T22:25:19","modified_gmt":"2026-09-19T22:25:19","slug":"jeux-de-barres-cuivre-ou-aluminium","status":"publish","type":"post","link":"https:\/\/devpan.com\/fr\/jeux-de-barres-cuivre-ou-aluminium\/","title":{"rendered":"Jeux de barres : cuivre ou aluminium ? Crit\u00e8res de choix"},"content":{"rendered":"\n<div class=\"dvp-toc dvp-geo\"><strong>R\u00e9ponse rapide<\/strong><p>Comparaison pratique des jeux de barres cuivre et aluminium : conductivit\u00e9, section, poids, co\u00fbt et fiabilit\u00e9 des raccordements.<\/p><strong class=\"dvp-toc-2\">Sommaire<\/strong><ol><li><a href=\"#section-1\">Quel est le r\u00f4le r\u00e9el d&rsquo;un jeu de barres ?<\/a><\/li><li><a href=\"#section-2\">Les atouts du cuivre<\/a><\/li><li><a href=\"#section-3\">Quand l&rsquo;aluminium est le bon choix<\/a><\/li><li><a href=\"#section-4\">Tableau comparatif cuivre \/ aluminium<\/a><\/li><li><a href=\"#section-5\">Six points critiques pour dimensionner une barre<\/a><\/li><li><a href=\"#section-6\">Les raccordements : l\u00e0 o\u00f9 naissent r\u00e9ellement les d\u00e9fauts<\/a><\/li><li><a href=\"#section-7\">Rev\u00eatement : nu, \u00e9tam\u00e9, nickel\u00e9 ou argent\u00e9<\/a><\/li><li><a href=\"#dvp-ozet\">Points cl\u00e9s<\/a><\/li><li><a href=\"#section-8\">Questions fr\u00e9quentes<\/a><\/li><li><a href=\"#dvp-ilgili\">Articles li\u00e9s<\/a><\/li><\/ol><\/div>\n\n\n\n<p class=\"wp-block-paragraph\">Les <strong>jeux de barres<\/strong> constituent la colonne vert\u00e9brale d&rsquo;un tableau basse tension : ils transportent l&rsquo;\u00e9nergie depuis l&rsquo;appareil d&rsquo;arriv\u00e9e jusqu&rsquo;\u00e0 chaque d\u00e9part. Si l&rsquo;on utilise des profil\u00e9s plats plut\u00f4t que des c\u00e2bles, la raison est simple : ils v\u00e9hiculent des courants \u00e9lev\u00e9s dans un volume r\u00e9duit, avec moins de pertes, et ils peuvent \u00eatre d\u00e9riv\u00e9s sur toute leur longueur. Le mat\u00e9riau de cette colonne vert\u00e9brale d\u00e9termine directement le co\u00fbt, le poids, l&rsquo;encombrement et le risque de d\u00e9faillance \u00e0 long terme. Et la discussion commence toujours au m\u00eame endroit : cuivre ou aluminium ?<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"section-1\">Quel est le r\u00f4le r\u00e9el d&rsquo;un jeu de barres ?<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Un jeu de barres remplit trois fonctions simultan\u00e9ment. Il transporte le courant : quel que soit le courant assign\u00e9 de l&rsquo;appareil d&rsquo;arriv\u00e9e, la barre principale doit le v\u00e9hiculer en permanence sans d\u00e9passer les limites d&rsquo;\u00e9chauffement. Il assure une tenue m\u00e9canique : lors d&rsquo;un court-circuit, les efforts \u00e9lectrodynamiques entre barres voisines peuvent atteindre l&rsquo;ordre de la tonne, et l&rsquo;ensemble barres et isolateurs doit y r\u00e9sister sans d\u00e9formation permanente. Il organise enfin la distribution, en permettant \u00e0 des dizaines de d\u00e9parts de se raccorder au m\u00eame potentiel de fa\u00e7on reproductible et contr\u00f4lable.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Aucune de ces fonctions n&rsquo;est ind\u00e9pendante du mat\u00e9riau. La conductivit\u00e9 fixe la capacit\u00e9 de courant, la densit\u00e9 fixe le poids et la structure porteuse, les propri\u00e9t\u00e9s m\u00e9caniques fixent la tenue au court-circuit, et le comportement de surface fixe la dur\u00e9e de vie de chaque raccordement.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"section-2\">Les atouts du cuivre<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Le cuivre est le mat\u00e9riau de r\u00e9f\u00e9rence de la distribution \u00e9lectrique. Avec une conductivit\u00e9 d&rsquo;environ 58 MS\/m, il transporte le m\u00eame courant dans une section sensiblement plus faible que l&rsquo;aluminium. Cela se traduit directement par un tableau plus compact, ce qui devient d\u00e9cisif lorsque la gaine \u00e0 barres est \u00e9troite, la profondeur de la cellule limit\u00e9e, ou le nombre de barres en parall\u00e8le important.<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Section plus faible pour un m\u00eame courant, donc gaine \u00e0 barres r\u00e9duite et tableau plus compact<\/li>\n\n<li>L&rsquo;oxyde de cuivre form\u00e9 en surface est conducteur : la r\u00e9sistance de contact d\u00e9rive moins dans le temps<\/li>\n\n<li>R\u00e9sistance m\u00e9canique et module plus \u00e9lev\u00e9s, autorisant des port\u00e9es plus longues entre isolateurs<\/li>\n\n<li>Fluage tr\u00e8s faible : les assemblages boulonn\u00e9s perdent leur pr\u00e9charge beaucoup plus lentement<\/li>\n\n<li>Avec un rev\u00eatement \u00e9tain, nickel ou argent, r\u00e9sistance de contact extr\u00eamement basse aux fortes intensit\u00e9s<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"section-3\">Quand l&rsquo;aluminium est le bon choix<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">L&rsquo;aluminium offre environ 61 \u00e0 62 % de la conductivit\u00e9 du cuivre, mais seulement un tiers de sa densit\u00e9. M\u00eame en augmentant la section d&rsquo;un facteur voisin de 1,6 pour un m\u00eame courant, la barre obtenue reste plus l\u00e9g\u00e8re que le cuivre. Sur les longs cheminements de barres principales et dans les projets sensibles au co\u00fbt, cet avantage devient tr\u00e8s net.<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Poids souvent inf\u00e9rieur de moiti\u00e9 \u00e0 celui du cuivre : transport, manutention et charge de structure r\u00e9duits<\/li>\n\n<li>Co\u00fbt mati\u00e8re nettement plus bas et moins expos\u00e9 \u00e0 la volatilit\u00e9 des cours<\/li>\n\n<li>Co\u00fbt global de possession r\u00e9duit sur les longues liaisons principales et les canalisations pr\u00e9fabriqu\u00e9es<\/li>\n\n<li>Surface d&rsquo;\u00e9change plus grande, donc \u00e9chauffement ma\u00eetrisable si la section est correctement choisie<\/li>\n\n<li>Risque de vol sur chantier plus faible du fait d&rsquo;une valeur de revente moindre<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"section-4\">Tableau comparatif cuivre \/ aluminium<\/h2>\n\n\n\n<figure class=\"wp-block-table\"><table><thead><tr><th>Crit\u00e8re<\/th><th>Cuivre (Cu)<\/th><th>Aluminium (Al)<\/th><\/tr><\/thead><tbody><tr><td>Conductivit\u00e9 \u00e9lectrique<\/td><td>~58 MS\/m (r\u00e9f\u00e9rence 100 % IACS)<\/td><td>~37 MS\/m (environ 61-62 % IACS)<\/td><\/tr><tr><td>Section pour un m\u00eame courant<\/td><td>R\u00e9f\u00e9rence<\/td><td>Environ 1,55 \u00e0 1,65 fois plus grande<\/td><\/tr><tr><td>Poids pour un m\u00eame courant<\/td><td>R\u00e9f\u00e9rence<\/td><td>Environ 45 \u00e0 55 % plus l\u00e9ger<\/td><\/tr><tr><td>Masse volumique<\/td><td>8,9 g\/cm\u00b3<\/td><td>2,7 g\/cm\u00b3<\/td><\/tr><tr><td>Co\u00fbt mati\u00e8re<\/td><td>\u00c9lev\u00e9<\/td><td>Nettement plus faible<\/td><\/tr><tr><td>Oxyde de surface<\/td><td>Conducteur, favorable au contact<\/td><td>Al\u2082O\u2083 isolant ; pr\u00e9paration de surface obligatoire<\/td><\/tr><tr><td>Assemblage boulonn\u00e9<\/td><td>Stable, perte de pr\u00e9charge lente<\/td><td>Sensible au fluage ; rondelles \u00e9lastiques et couple contr\u00f4l\u00e9 indispensables<\/td><\/tr><tr><td>Dilatation thermique<\/td><td>~17 \u00b5m\/m\u00b7K<\/td><td>~23 \u00b5m\/m\u00b7K<\/td><\/tr><tr><td>Usage typique<\/td><td>Tableaux compacts, forte densit\u00e9 de courant, raccordements de cellules MT<\/td><td>Longues liaisons principales, canalisations, projets orient\u00e9s co\u00fbt<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<figure class=\"dvp-figure\" style=\"margin:2.2em 0\"><svg viewBox=\"0 0 720 260\" width=\"100%\" style=\"height:auto;max-width:720px;display:block;margin:0 auto\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><rect x=\"0\" y=\"0\" width=\"720\" height=\"260\" rx=\"12\" fill=\"#f5f8fa\"\/><g font-family=\"Inter,Arial,sans-serif\" font-size=\"14\" fill=\"#2b3a4a\"><rect x=\"60\" y=\"80\" width=\"140\" height=\"26\" rx=\"3\" fill=\"#b87333\"\/><line x1=\"60\" y1=\"62\" x2=\"200\" y2=\"62\" stroke=\"#7b8794\"\/><text x=\"130\" y=\"52\" text-anchor=\"middle\" font-size=\"12\" fill=\"#5a6b7b\">60 mm<\/text><text x=\"130\" y=\"138\" text-anchor=\"middle\" font-weight=\"600\">Cuivre &#8211; Cu<\/text><text x=\"130\" y=\"160\" text-anchor=\"middle\" font-size=\"12\" fill=\"#5a6b7b\">60 x 10 mm = 600 mm2<\/text><text x=\"130\" y=\"180\" text-anchor=\"middle\" font-size=\"12\" fill=\"#5a6b7b\">~58 MS\/m<\/text><line x1=\"360\" y1=\"40\" x2=\"360\" y2=\"216\" stroke=\"#d5dee5\" stroke-width=\"2\" stroke-dasharray=\"6 6\"\/><text x=\"360\" y=\"234\" text-anchor=\"middle\" font-size=\"13\" fill=\"#1D8BCB\" font-weight=\"600\">m\u00eame courant<\/text><rect x=\"470\" y=\"76\" width=\"180\" height=\"34\" rx=\"3\" fill=\"#a6b1bb\"\/><line x1=\"470\" y1=\"58\" x2=\"650\" y2=\"58\" stroke=\"#7b8794\"\/><text x=\"560\" y=\"48\" text-anchor=\"middle\" font-size=\"12\" fill=\"#5a6b7b\">100 mm<\/text><text x=\"560\" y=\"138\" text-anchor=\"middle\" font-weight=\"600\">Aluminium &#8211; Al<\/text><text x=\"560\" y=\"160\" text-anchor=\"middle\" font-size=\"12\" fill=\"#5a6b7b\">100 x 10 mm = 1000 mm2<\/text><text x=\"560\" y=\"180\" text-anchor=\"middle\" font-size=\"12\" fill=\"#5a6b7b\">~37 MS\/m<\/text><text x=\"360\" y=\"20\" text-anchor=\"middle\" font-size=\"12\" fill=\"#7b8794\">devpan.com<\/text><\/g><\/svg><figcaption style=\"font-size:.88em;opacity:.75;text-align:center;margin-top:.7em\">Comparaison sch\u00e9matique des sections de cuivre et d&rsquo;aluminium n\u00e9cessaires pour v\u00e9hiculer le m\u00eame courant.<\/figcaption><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"section-5\">Six points critiques pour dimensionner une barre<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Choisir une section directement dans un tableau de catalogue est l&rsquo;erreur la plus fr\u00e9quente. Les valeurs catalogue ne sont valables que dans des conditions de r\u00e9f\u00e9rence d\u00e9finies, et un tableau r\u00e9el ne correspond jamais exactement \u00e0 ces conditions.<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Courant assign\u00e9 et facteur de simultan\u00e9it\u00e9 : le profil de charge r\u00e9el diff\u00e8re souvent du calibre d&rsquo;arriv\u00e9e<\/li>\n\n<li>Temp\u00e9rature ambiante et \u00e9chauffement interne : un choix fait pour 35 \u00b0C n&rsquo;est plus valable \u00e0 50 \u00b0C<\/li>\n\n<li>Disposition des barres et effet de proximit\u00e9 : des barres juxtapos\u00e9es emp\u00eachent leur propre refroidissement<\/li>\n\n<li>Orientation de montage : une barre pos\u00e9e sur chant refroidit mieux qu&rsquo;une barre \u00e0 plat<\/li>\n\n<li>Tenue au court-circuit : la valeur Icw impose la section et l&rsquo;entraxe des isolateurs<\/li>\n\n<li>Indice de protection et ventilation : une enveloppe IP54 \u00e9tanche s&rsquo;\u00e9chauffe bien plus vite qu&rsquo;une IP31<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Tous ces param\u00e8tres doivent \u00eatre \u00e9valu\u00e9s avec la v\u00e9rification de l&rsquo;\u00e9chauffement exig\u00e9e par la CEI 61439-1. Pour le cadre plus large du choix de la barre principale, voir notre article sur les <a href=\"https:\/\/devpan.com\/fr\/tableau-general-basse-tension-tgbt\/\">crit\u00e8res de choix du tableau g\u00e9n\u00e9ral basse tension<\/a>.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"section-6\">Les raccordements : l\u00e0 o\u00f9 naissent r\u00e9ellement les d\u00e9fauts<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">La plupart des d\u00e9faillances n&rsquo;apparaissent pas dans la barre elle-m\u00eame mais aux raccordements. La r\u00e9sistance de contact augmente, le point chauffe, l&rsquo;oxydation s&rsquo;acc\u00e9l\u00e8re, la r\u00e9sistance cro\u00eet encore et le ph\u00e9nom\u00e8ne d\u00e9g\u00e9n\u00e8re en emballement thermique. Avec l&rsquo;aluminium le risque est double : la couche d&rsquo;oxyde isolante qui se forme presque instantan\u00e9ment, et le fluage du m\u00e9tal qui fait chuter la pr\u00e9charge des boulons avec le temps.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Les contre-mesures sont bien connues. Les surfaces en aluminium sont bross\u00e9es juste avant l&rsquo;assemblage puis prot\u00e9g\u00e9es par une graisse de contact adapt\u00e9e. Les assemblages boulonn\u00e9s sont serr\u00e9s au couple prescrit par le fabricant et recontr\u00f4l\u00e9s apr\u00e8s une dur\u00e9e de service d\u00e9finie. Des rondelles \u00e9lastiques ou coniques compensent la perte de pr\u00e9charge. Partout o\u00f9 le cuivre rencontre directement l&rsquo;aluminium, une pi\u00e8ce bim\u00e9tallique ou un \u00e9tamage \u00e9vite la corrosion galvanique. Enfin, relever les temp\u00e9ratures des raccordements \u00e0 la cam\u00e9ra thermique apr\u00e8s mise en service cr\u00e9e une r\u00e9f\u00e9rence pour toutes les visites ult\u00e9rieures.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"section-7\">Rev\u00eatement : nu, \u00e9tam\u00e9, nickel\u00e9 ou argent\u00e9<\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Cuivre nu : solution \u00e9conomique en int\u00e9rieur, en faible humidit\u00e9, sur des raccordements accessibles<\/li>\n\n<li>\u00c9tamage : le choix le plus courant, il retarde l&rsquo;oxydation et s\u00e9curise les liaisons cuivre-aluminium<\/li>\n\n<li>Nickelage : r\u00e9sistant en temp\u00e9rature \u00e9lev\u00e9e et en atmosph\u00e8re agressive, r\u00e9sistance de contact un peu sup\u00e9rieure \u00e0 l&rsquo;\u00e9tain<\/li>\n\n<li>Argenture : la plus faible r\u00e9sistance de contact, r\u00e9serv\u00e9e aux contacts d\u00e9brochables et aux fortes intensit\u00e9s<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"dvp-ozet\">Points cl\u00e9s: jeux de barres<\/h2>\n\n\n\n<ul class=\"dvp-check dvp-geo\"><li><strong>Quel est le r\u00f4le r\u00e9el d&rsquo;un jeu de barres <\/strong> \u2014 Un jeu de barres remplit trois fonctions simultan\u00e9ment.<\/li><li><strong>Les atouts du cuivre<\/strong> \u2014 Le cuivre est le mat\u00e9riau de r\u00e9f\u00e9rence de la distribution \u00e9lectrique.<\/li><li><strong>Quand l&rsquo;aluminium est le bon choix<\/strong> \u2014 L&rsquo;aluminium offre environ 61 \u00e0 62 % de la conductivit\u00e9 du cuivre, mais seulement un tiers de sa densit\u00e9.<\/li><li><strong>Six points critiques pour dimensionner une barre<\/strong> \u2014 Choisir une section directement dans un tableau de catalogue est l&rsquo;erreur la plus fr\u00e9quente.<\/li><li><strong>Source normative<\/strong> \u2014 catalogue des publications IEC: <a href=\"https:\/\/www.iec.ch\/\">iec.ch<\/a>.<\/li><\/ul>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"section-8\">Questions fr\u00e9quentes<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\">L&rsquo;aluminium augmente-t-il la taille du tableau ?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Oui. Pour un m\u00eame courant la section cro\u00eet d&rsquo;un facteur voisin de 1,6, ce qui se traduit g\u00e9n\u00e9ralement par une gaine \u00e0 barres plus haute ou une enveloppe plus profonde. En contrepartie le poids diminue et la structure s&rsquo;all\u00e8ge : sauf contrainte forte d&#8217;emprise au sol, cette augmentation reste acceptable.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Peut-on associer cuivre et aluminium dans un m\u00eame tableau ?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Oui, mais l&rsquo;interface entre les deux m\u00e9taux est expos\u00e9e \u00e0 la corrosion galvanique. Elle exige une plaque bim\u00e9tallique, une surface \u00e9tam\u00e9e ou une pi\u00e8ce de transition adapt\u00e9e, et doit figurer dans le plan de contr\u00f4le du couple et des temp\u00e9ratures.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Comment valider une section de barre ?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Le calcul de conception n&rsquo;est qu&rsquo;un point de d\u00e9part. La validation r\u00e9elle passe par les v\u00e9rifications d&rsquo;\u00e9chauffement et de tenue au court-circuit d\u00e9finies par la CEI 61439. Respecter les r\u00e8gles d&rsquo;une conception d\u00e9j\u00e0 valid\u00e9e par essais de type est plus rapide et plus fiable que d&rsquo;essayer chaque tableau.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"dvp-ilgili\">Articles li\u00e9s<\/h2>\n\n\n\n<ul class=\"dvp-rel dvp-geo\"><li><a href=\"https:\/\/devpan.com\/fr\/capacite-de-courant-des-barres-et-declassement\/\">Capacit\u00e9 de courant des jeux de barres et calcul de d\u00e9classement<\/a><\/li><li><a href=\"https:\/\/devpan.com\/fr\/dimensionner-barres-neutre-et-terre\/\">Dimensionner les barres de neutre et de terre dans un tableau<\/a><\/li><li><a href=\"https:\/\/devpan.com\/fr\/section-de-cable-et-calcul-de-chute-de-tension\/\">Choix de la section de c\u00e2ble et calcul de la chute de tension<\/a><\/li><li><a href=\"https:\/\/devpan.com\/fr\/entreprise\/articles\/\">Tous les articles techniques<\/a><\/li><\/ul><p>Solution Devpan associ\u00e9e : <a href=\"https:\/\/devpan.com\/fr\/tableaux-electriques-et-appareillage-moyenne-tension\/tableaux-basse-tension\/tableau-general-basse-tension-devpanel\/\">tableau g\u00e9n\u00e9ral basse tension DevPanel<\/a>.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Chez Devpan, nous dimensionnons le jeu de barres avec le profil de courant, la tenue au court-circuit, la temp\u00e9rature ambiante et les conditions de site du projet, en appliquant des r\u00e8gles de conception valid\u00e9es par essais de type pour le cuivre comme pour l&rsquo;aluminium. Transmettez-nous votre sch\u00e9ma unifilaire et nous \u00e9tablirons une comparaison section, poids et co\u00fbt des deux solutions.<\/p>\n\n\n\n<script type=\"application\/ld+json\">{\"@context\":\"https:\/\/schema.org\",\"@type\":\"FAQPage\",\"inLanguage\":\"fr\",\"mainEntity\":[{\"@type\":\"Question\",\"name\":\"L'aluminium augmente-t-il la taille du tableau ?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Oui. Pour un m\u00eame courant la section cro\u00eet d'un facteur voisin de 1,6, ce qui se traduit g\u00e9n\u00e9ralement par une gaine \u00e0 barres plus haute ou une enveloppe plus profonde. En contrepartie le poids diminue et la structure s'all\u00e8ge : sauf contrainte forte d'emprise au sol, cette augmentation reste acceptable.\"}},{\"@type\":\"Question\",\"name\":\"Peut-on associer cuivre et aluminium dans un m\u00eame tableau ?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Oui, mais l'interface entre les deux m\u00e9taux est expos\u00e9e \u00e0 la corrosion galvanique. Elle exige une plaque bim\u00e9tallique, une surface \u00e9tam\u00e9e ou une pi\u00e8ce de transition adapt\u00e9e, et doit figurer dans le plan de contr\u00f4le du couple et des temp\u00e9ratures.\"}},{\"@type\":\"Question\",\"name\":\"Comment valider une section de barre ?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Le calcul de conception n'est qu'un point de d\u00e9part. La validation r\u00e9elle passe par les v\u00e9rifications d'\u00e9chauffement et de tenue au court-circuit d\u00e9finies par la CEI 61439. Respecter les r\u00e8gles d'une conception d\u00e9j\u00e0 valid\u00e9e par essais de type est plus rapide et plus fiable que d'essayer chaque tableau. Chez Devpan, nous dimensionnons le jeu de barres avec le profil de courant, la tenue au court-circuit, la temp\u00e9rature ambiante et les conditions de site du projet, en appliquant des r\u00e8gles de conception valid\u00e9es par essais de type pour le cuivre comme pour l'aluminium. Transmettez-nous votre sch\u00e9ma unifilaire et nous \u00e9tablirons une comparaison section, poids et co\u00fbt des deux solutions.\"}}]}<\/script>\n","protected":false},"excerpt":{"rendered":"<p>Comparaison pratique des jeux de barres cuivre et aluminium : conductivit\u00e9, section, poids, co\u00fbt et fiabilit\u00e9 des raccordements.<\/p>\n","protected":false},"author":1,"featured_media":12174,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[77],"tags":[],"class_list":["post-12119","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-articles-techniques"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.4 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Jeux de barres : cuivre ou aluminium ? | Devpan<\/title>\n<meta name=\"description\" content=\"Comparaison des jeux de barres cuivre et aluminium en basse tension : conductivit\u00e9, section, poids, co\u00fbt, raccordements et rev\u00eatements.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/devpan.com\/fr\/jeux-de-barres-cuivre-ou-aluminium\/\" \/>\n<meta property=\"og:locale\" content=\"fr_FR\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Jeux de barres : cuivre ou aluminium ? | Devpan\" \/>\n<meta property=\"og:description\" content=\"Comparaison des jeux de barres cuivre et aluminium en basse tension : conductivit\u00e9, section, poids, co\u00fbt, raccordements et rev\u00eatements.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/devpan.com\/fr\/jeux-de-barres-cuivre-ou-aluminium\/\" \/>\n<meta property=\"og:site_name\" content=\"Devpan\" \/>\n<meta property=\"article:published_time\" content=\"2026-08-16T19:35:49+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-09-19T22:25:19+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/devpan.com\/wp-content\/uploads\/2026\/08\/dvp-jdb-cuivre-aluminium-fr-v2.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1200\" \/>\n\t<meta property=\"og:image:height\" content=\"630\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"admin\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"\u00c9crit par\" \/>\n\t<meta name=\"twitter:data1\" content=\"admin\" \/>\n\t<meta name=\"twitter:label2\" content=\"Dur\u00e9e de lecture estim\u00e9e\" \/>\n\t<meta name=\"twitter:data2\" content=\"8 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/devpan.com\\\/fr\\\/jeux-de-barres-cuivre-ou-aluminium\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/devpan.com\\\/fr\\\/jeux-de-barres-cuivre-ou-aluminium\\\/\"},\"author\":{\"name\":\"admin\",\"@id\":\"https:\\\/\\\/devpan.com\\\/fr\\\/#\\\/schema\\\/person\\\/3c5324d50ad0d58be167633ef55c943c\"},\"headline\":\"Jeux de barres : cuivre ou aluminium ? Crit\u00e8res de choix\",\"datePublished\":\"2026-08-16T19:35:49+00:00\",\"dateModified\":\"2026-09-19T22:25:19+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/devpan.com\\\/fr\\\/jeux-de-barres-cuivre-ou-aluminium\\\/\"},\"wordCount\":1743,\"publisher\":{\"@id\":\"https:\\\/\\\/devpan.com\\\/fr\\\/#organization\"},\"image\":{\"@id\":\"https:\\\/\\\/devpan.com\\\/fr\\\/jeux-de-barres-cuivre-ou-aluminium\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/devpan.com\\\/wp-content\\\/uploads\\\/2026\\\/08\\\/dvp-jdb-cuivre-aluminium-fr-v2.jpg\",\"articleSection\":[\"Articles techniques\"],\"inLanguage\":\"fr-FR\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/devpan.com\\\/fr\\\/jeux-de-barres-cuivre-ou-aluminium\\\/\",\"url\":\"https:\\\/\\\/devpan.com\\\/fr\\\/jeux-de-barres-cuivre-ou-aluminium\\\/\",\"name\":\"Jeux de barres : cuivre ou aluminium ? | Devpan\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/devpan.com\\\/fr\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/devpan.com\\\/fr\\\/jeux-de-barres-cuivre-ou-aluminium\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/devpan.com\\\/fr\\\/jeux-de-barres-cuivre-ou-aluminium\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/devpan.com\\\/wp-content\\\/uploads\\\/2026\\\/08\\\/dvp-jdb-cuivre-aluminium-fr-v2.jpg\",\"datePublished\":\"2026-08-16T19:35:49+00:00\",\"dateModified\":\"2026-09-19T22:25:19+00:00\",\"description\":\"Comparaison des jeux de barres cuivre et aluminium en basse tension : conductivit\u00e9, section, poids, co\u00fbt, raccordements et rev\u00eatements.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/devpan.com\\\/fr\\\/jeux-de-barres-cuivre-ou-aluminium\\\/#breadcrumb\"},\"inLanguage\":\"fr-FR\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/devpan.com\\\/fr\\\/jeux-de-barres-cuivre-ou-aluminium\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\\\/\\\/devpan.com\\\/fr\\\/jeux-de-barres-cuivre-ou-aluminium\\\/#primaryimage\",\"url\":\"https:\\\/\\\/devpan.com\\\/wp-content\\\/uploads\\\/2026\\\/08\\\/dvp-jdb-cuivre-aluminium-fr-v2.jpg\",\"contentUrl\":\"https:\\\/\\\/devpan.com\\\/wp-content\\\/uploads\\\/2026\\\/08\\\/dvp-jdb-cuivre-aluminium-fr-v2.jpg\",\"width\":1200,\"height\":630,\"caption\":\"Sch\u00e9ma comparant les sections de barres en cuivre et en aluminium\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/devpan.com\\\/fr\\\/jeux-de-barres-cuivre-ou-aluminium\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Accueil\",\"item\":\"https:\\\/\\\/devpan.com\\\/fr\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Jeux de barres : cuivre ou aluminium ? Crit\u00e8res de choix\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/devpan.com\\\/fr\\\/#website\",\"url\":\"https:\\\/\\\/devpan.com\\\/fr\\\/\",\"name\":\"Devpan\",\"description\":\"Tableaux basse et moyenne tension\",\"publisher\":{\"@id\":\"https:\\\/\\\/devpan.com\\\/fr\\\/#organization\"},\"alternateName\":\"Devpan Elektrik Panolar\u0131\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/devpan.com\\\/fr\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"fr-FR\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/devpan.com\\\/fr\\\/#organization\",\"name\":\"Devpan\",\"alternateName\":[\"Devpan Electric\",\"Devpan Pano\"],\"url\":\"https:\\\/\\\/devpan.com\\\/fr\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\\\/\\\/devpan.com\\\/fr\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/devpan.com\\\/wp-content\\\/uploads\\\/2026\\\/07\\\/devpan-logo.png\",\"contentUrl\":\"https:\\\/\\\/devpan.com\\\/wp-content\\\/uploads\\\/2026\\\/07\\\/devpan-logo.png\",\"width\":1000,\"height\":350,\"caption\":\"Devpan\"},\"image\":{\"@id\":\"https:\\\/\\\/devpan.com\\\/fr\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.linkedin.com\\\/company\\\/devpan-pano\\\/\",\"https:\\\/\\\/www.instagram.com\\\/devpanelectric\\\/\",\"https:\\\/\\\/www.youtube.com\\\/@devpanpano2205\"],\"description\":\"Devpan con\u00e7oit et fabrique, dans son usine de Dudullu OSB \u00e0 Istanbul, des tableaux basse tension principaux et divisionnaires conformes \u00e0 l\u2019IEC 61439, des centres de commande moteurs (MCC), des tableaux de compensation et des cellules modulaires moyenne tension.\",\"foundingDate\":\"2012\",\"email\":\"info@devpan.com\",\"telephone\":\"+90 216 660 05 72\",\"address\":{\"@type\":\"PostalAddress\",\"streetAddress\":\"Dudullu OSB Mah. 1. Cadde No: 28\",\"addressLocality\":\"\u00dcmraniye\",\"addressRegion\":\"\u0130stanbul\",\"addressCountry\":\"TR\"},\"location\":[{\"@type\":\"Place\",\"name\":\"Devpan \u2013 Headquarters and factory\",\"address\":{\"@type\":\"PostalAddress\",\"streetAddress\":\"Dudullu OSB Mah. 1. Cadde No: 28\",\"addressLocality\":\"\u00dcmraniye\",\"addressRegion\":\"\u0130stanbul\",\"addressCountry\":\"TR\"}},{\"@type\":\"Place\",\"name\":\"Devpan \u2013 Africa office\",\"address\":{\"@type\":\"PostalAddress\",\"streetAddress\":\"Zone SAHRAOUI, 2429 Ksar\",\"addressLocality\":\"Nouakchott\",\"addressCountry\":\"MR\"}},{\"@type\":\"Place\",\"name\":\"Devpan \u2013 Russia office\",\"address\":{\"@type\":\"PostalAddress\",\"streetAddress\":\"\u0443\u043b. \u041c\u0435\u0436\u0434\u0443\u043d\u0430\u0440\u043e\u0434\u043d\u0430\u044f, \u0434. 14\",\"addressLocality\":\"\u041a\u0440\u0430\u0441\u043d\u043e\u0433\u043e\u0440\u0441\u043a\",\"addressRegion\":\"\u041c\u043e\u0441\u043a\u043e\u0432\u0441\u043a\u0430\u044f \u043e\u0431\u043b.\",\"postalCode\":\"143402\",\"addressCountry\":\"RU\"}}],\"contactPoint\":[{\"@type\":\"ContactPoint\",\"contactType\":\"sales\",\"telephone\":\"+90-216-660-05-72\",\"email\":\"info@devpan.com\",\"availableLanguage\":[\"Turkish\",\"English\"],\"url\":\"https:\\\/\\\/devpan.com\\\/fr\\\/contact\\\/\"},{\"@type\":\"ContactPoint\",\"contactType\":\"customer support\",\"email\":\"service@devpan.com\",\"availableLanguage\":[\"Turkish\",\"English\"],\"url\":\"https:\\\/\\\/devpan.com\\\/fr\\\/contact\\\/\"},{\"@type\":\"ContactPoint\",\"contactType\":\"sales\",\"telephone\":\"+222-36-30-00-24\",\"email\":\"elycheikh@devpan.com\",\"areaServed\":\"MR\",\"availableLanguage\":[\"French\",\"Arabic\"],\"url\":\"https:\\\/\\\/devpan.com\\\/fr\\\/contact\\\/\"},{\"@type\":\"ContactPoint\",\"contactType\":\"sales\",\"telephone\":\"+7-966-128-38-88\",\"email\":\"a.permanov@devpan.com\",\"areaServed\":\"RU\",\"availableLanguage\":[\"Russian\"],\"url\":\"https:\\\/\\\/devpan.com\\\/fr\\\/contact\\\/\"}],\"hasCredential\":[{\"@type\":\"EducationalOccupationalCredential\",\"credentialCategory\":\"certificate\",\"name\":\"Certificat d\u2019essai de type \u2013 enveloppe vide\",\"url\":\"https:\\\/\\\/devpan.com\\\/fr\\\/entreprise\\\/certifications\\\/\"},{\"@type\":\"EducationalOccupationalCredential\",\"credentialCategory\":\"certificate\",\"name\":\"Certificat d\u2019essai de type Legrand 4000 A\",\"url\":\"https:\\\/\\\/devpan.com\\\/fr\\\/entreprise\\\/certifications\\\/\"},{\"@type\":\"EducationalOccupationalCredential\",\"credentialCategory\":\"certificate\",\"name\":\"Certificat d\u2019essai de type ABB 4000 A\",\"url\":\"https:\\\/\\\/devpan.com\\\/fr\\\/entreprise\\\/certifications\\\/\"},{\"@type\":\"EducationalOccupationalCredential\",\"credentialCategory\":\"certificate\",\"name\":\"Certificat CE \u2013 enveloppe vide\",\"url\":\"https:\\\/\\\/devpan.com\\\/fr\\\/entreprise\\\/certifications\\\/\"},{\"@type\":\"EducationalOccupationalCredential\",\"credentialCategory\":\"certificate\",\"name\":\"Certificat CE Legrand 4000 A\",\"url\":\"https:\\\/\\\/devpan.com\\\/fr\\\/entreprise\\\/certifications\\\/\"},{\"@type\":\"EducationalOccupationalCredential\",\"credentialCategory\":\"certificate\",\"name\":\"Certificat CE ABB 4000 A\",\"url\":\"https:\\\/\\\/devpan.com\\\/fr\\\/entreprise\\\/certifications\\\/\"},{\"@type\":\"EducationalOccupationalCredential\",\"credentialCategory\":\"certificate\",\"name\":\"Certificat d\u2019essai sismique\",\"url\":\"https:\\\/\\\/devpan.com\\\/fr\\\/entreprise\\\/certifications\\\/\"},{\"@type\":\"EducationalOccupationalCredential\",\"credentialCategory\":\"certificate\",\"name\":\"Certificat GOST\",\"url\":\"https:\\\/\\\/devpan.com\\\/fr\\\/entreprise\\\/certifications\\\/\"},{\"@type\":\"EducationalOccupationalCredential\",\"credentialCategory\":\"certificate\",\"name\":\"Certificat ISO 9001 \u2013 syst\u00e8me de management de la qualit\u00e9\",\"url\":\"https:\\\/\\\/devpan.com\\\/fr\\\/entreprise\\\/certifications\\\/\"}],\"knowsAbout\":[\"IEC 61439\",\"Low-voltage switchgear and controlgear assemblies\",\"Main distribution boards\",\"Motor control centres (MCC)\",\"Power factor correction panels\",\"Medium-voltage switchgear\",\"Ring main units (RMU)\",\"Busbar systems\",\"Industrial automation and SCADA\"]},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/devpan.com\\\/fr\\\/#\\\/schema\\\/person\\\/3c5324d50ad0d58be167633ef55c943c\",\"name\":\"admin\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/8caee90c0299048f405dbeffa66ec71ea4c1d3c3ed137bda9fbdd550b6c3983e?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/8caee90c0299048f405dbeffa66ec71ea4c1d3c3ed137bda9fbdd550b6c3983e?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/8caee90c0299048f405dbeffa66ec71ea4c1d3c3ed137bda9fbdd550b6c3983e?s=96&d=mm&r=g\",\"caption\":\"admin\"},\"sameAs\":[\"https:\\\/\\\/devpan.com\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Jeux de barres : cuivre ou aluminium ? | Devpan","description":"Comparaison des jeux de barres cuivre et aluminium en basse tension : conductivit\u00e9, section, poids, co\u00fbt, raccordements et rev\u00eatements.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/devpan.com\/fr\/jeux-de-barres-cuivre-ou-aluminium\/","og_locale":"fr_FR","og_type":"article","og_title":"Jeux de barres : cuivre ou aluminium ? | Devpan","og_description":"Comparaison des jeux de barres cuivre et aluminium en basse tension : conductivit\u00e9, section, poids, co\u00fbt, raccordements et rev\u00eatements.","og_url":"https:\/\/devpan.com\/fr\/jeux-de-barres-cuivre-ou-aluminium\/","og_site_name":"Devpan","article_published_time":"2026-08-16T19:35:49+00:00","article_modified_time":"2026-09-19T22:25:19+00:00","og_image":[{"width":1200,"height":630,"url":"https:\/\/devpan.com\/wp-content\/uploads\/2026\/08\/dvp-jdb-cuivre-aluminium-fr-v2.jpg","type":"image\/jpeg"}],"author":"admin","twitter_card":"summary_large_image","twitter_misc":{"\u00c9crit par":"admin","Dur\u00e9e de lecture estim\u00e9e":"8 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/devpan.com\/fr\/jeux-de-barres-cuivre-ou-aluminium\/#article","isPartOf":{"@id":"https:\/\/devpan.com\/fr\/jeux-de-barres-cuivre-ou-aluminium\/"},"author":{"name":"admin","@id":"https:\/\/devpan.com\/fr\/#\/schema\/person\/3c5324d50ad0d58be167633ef55c943c"},"headline":"Jeux de barres : cuivre ou aluminium ? Crit\u00e8res de choix","datePublished":"2026-08-16T19:35:49+00:00","dateModified":"2026-09-19T22:25:19+00:00","mainEntityOfPage":{"@id":"https:\/\/devpan.com\/fr\/jeux-de-barres-cuivre-ou-aluminium\/"},"wordCount":1743,"publisher":{"@id":"https:\/\/devpan.com\/fr\/#organization"},"image":{"@id":"https:\/\/devpan.com\/fr\/jeux-de-barres-cuivre-ou-aluminium\/#primaryimage"},"thumbnailUrl":"https:\/\/devpan.com\/wp-content\/uploads\/2026\/08\/dvp-jdb-cuivre-aluminium-fr-v2.jpg","articleSection":["Articles techniques"],"inLanguage":"fr-FR"},{"@type":"WebPage","@id":"https:\/\/devpan.com\/fr\/jeux-de-barres-cuivre-ou-aluminium\/","url":"https:\/\/devpan.com\/fr\/jeux-de-barres-cuivre-ou-aluminium\/","name":"Jeux de barres : cuivre ou aluminium ? | Devpan","isPartOf":{"@id":"https:\/\/devpan.com\/fr\/#website"},"primaryImageOfPage":{"@id":"https:\/\/devpan.com\/fr\/jeux-de-barres-cuivre-ou-aluminium\/#primaryimage"},"image":{"@id":"https:\/\/devpan.com\/fr\/jeux-de-barres-cuivre-ou-aluminium\/#primaryimage"},"thumbnailUrl":"https:\/\/devpan.com\/wp-content\/uploads\/2026\/08\/dvp-jdb-cuivre-aluminium-fr-v2.jpg","datePublished":"2026-08-16T19:35:49+00:00","dateModified":"2026-09-19T22:25:19+00:00","description":"Comparaison des jeux de barres cuivre et aluminium en basse tension : conductivit\u00e9, section, poids, co\u00fbt, raccordements et rev\u00eatements.","breadcrumb":{"@id":"https:\/\/devpan.com\/fr\/jeux-de-barres-cuivre-ou-aluminium\/#breadcrumb"},"inLanguage":"fr-FR","potentialAction":[{"@type":"ReadAction","target":["https:\/\/devpan.com\/fr\/jeux-de-barres-cuivre-ou-aluminium\/"]}]},{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/devpan.com\/fr\/jeux-de-barres-cuivre-ou-aluminium\/#primaryimage","url":"https:\/\/devpan.com\/wp-content\/uploads\/2026\/08\/dvp-jdb-cuivre-aluminium-fr-v2.jpg","contentUrl":"https:\/\/devpan.com\/wp-content\/uploads\/2026\/08\/dvp-jdb-cuivre-aluminium-fr-v2.jpg","width":1200,"height":630,"caption":"Sch\u00e9ma comparant les sections de barres en cuivre et en aluminium"},{"@type":"BreadcrumbList","@id":"https:\/\/devpan.com\/fr\/jeux-de-barres-cuivre-ou-aluminium\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Accueil","item":"https:\/\/devpan.com\/fr\/"},{"@type":"ListItem","position":2,"name":"Jeux de barres : cuivre ou aluminium ? Crit\u00e8res de choix"}]},{"@type":"WebSite","@id":"https:\/\/devpan.com\/fr\/#website","url":"https:\/\/devpan.com\/fr\/","name":"Devpan","description":"Tableaux basse et moyenne tension","publisher":{"@id":"https:\/\/devpan.com\/fr\/#organization"},"alternateName":"Devpan Elektrik Panolar\u0131","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/devpan.com\/fr\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"fr-FR"},{"@type":"Organization","@id":"https:\/\/devpan.com\/fr\/#organization","name":"Devpan","alternateName":["Devpan Electric","Devpan Pano"],"url":"https:\/\/devpan.com\/fr\/","logo":{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/devpan.com\/fr\/#\/schema\/logo\/image\/","url":"https:\/\/devpan.com\/wp-content\/uploads\/2026\/07\/devpan-logo.png","contentUrl":"https:\/\/devpan.com\/wp-content\/uploads\/2026\/07\/devpan-logo.png","width":1000,"height":350,"caption":"Devpan"},"image":{"@id":"https:\/\/devpan.com\/fr\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.linkedin.com\/company\/devpan-pano\/","https:\/\/www.instagram.com\/devpanelectric\/","https:\/\/www.youtube.com\/@devpanpano2205"],"description":"Devpan con\u00e7oit et fabrique, dans son usine de Dudullu OSB \u00e0 Istanbul, des tableaux basse tension principaux et divisionnaires conformes \u00e0 l\u2019IEC 61439, des centres de commande moteurs (MCC), des tableaux de compensation et des cellules modulaires moyenne tension.","foundingDate":"2012","email":"info@devpan.com","telephone":"+90 216 660 05 72","address":{"@type":"PostalAddress","streetAddress":"Dudullu OSB Mah. 1. Cadde No: 28","addressLocality":"\u00dcmraniye","addressRegion":"\u0130stanbul","addressCountry":"TR"},"location":[{"@type":"Place","name":"Devpan \u2013 Headquarters and factory","address":{"@type":"PostalAddress","streetAddress":"Dudullu OSB Mah. 1. Cadde No: 28","addressLocality":"\u00dcmraniye","addressRegion":"\u0130stanbul","addressCountry":"TR"}},{"@type":"Place","name":"Devpan \u2013 Africa office","address":{"@type":"PostalAddress","streetAddress":"Zone SAHRAOUI, 2429 Ksar","addressLocality":"Nouakchott","addressCountry":"MR"}},{"@type":"Place","name":"Devpan \u2013 Russia office","address":{"@type":"PostalAddress","streetAddress":"\u0443\u043b. \u041c\u0435\u0436\u0434\u0443\u043d\u0430\u0440\u043e\u0434\u043d\u0430\u044f, \u0434. 14","addressLocality":"\u041a\u0440\u0430\u0441\u043d\u043e\u0433\u043e\u0440\u0441\u043a","addressRegion":"\u041c\u043e\u0441\u043a\u043e\u0432\u0441\u043a\u0430\u044f \u043e\u0431\u043b.","postalCode":"143402","addressCountry":"RU"}}],"contactPoint":[{"@type":"ContactPoint","contactType":"sales","telephone":"+90-216-660-05-72","email":"info@devpan.com","availableLanguage":["Turkish","English"],"url":"https:\/\/devpan.com\/fr\/contact\/"},{"@type":"ContactPoint","contactType":"customer support","email":"service@devpan.com","availableLanguage":["Turkish","English"],"url":"https:\/\/devpan.com\/fr\/contact\/"},{"@type":"ContactPoint","contactType":"sales","telephone":"+222-36-30-00-24","email":"elycheikh@devpan.com","areaServed":"MR","availableLanguage":["French","Arabic"],"url":"https:\/\/devpan.com\/fr\/contact\/"},{"@type":"ContactPoint","contactType":"sales","telephone":"+7-966-128-38-88","email":"a.permanov@devpan.com","areaServed":"RU","availableLanguage":["Russian"],"url":"https:\/\/devpan.com\/fr\/contact\/"}],"hasCredential":[{"@type":"EducationalOccupationalCredential","credentialCategory":"certificate","name":"Certificat d\u2019essai de type \u2013 enveloppe vide","url":"https:\/\/devpan.com\/fr\/entreprise\/certifications\/"},{"@type":"EducationalOccupationalCredential","credentialCategory":"certificate","name":"Certificat d\u2019essai de type Legrand 4000 A","url":"https:\/\/devpan.com\/fr\/entreprise\/certifications\/"},{"@type":"EducationalOccupationalCredential","credentialCategory":"certificate","name":"Certificat d\u2019essai de type ABB 4000 A","url":"https:\/\/devpan.com\/fr\/entreprise\/certifications\/"},{"@type":"EducationalOccupationalCredential","credentialCategory":"certificate","name":"Certificat CE \u2013 enveloppe vide","url":"https:\/\/devpan.com\/fr\/entreprise\/certifications\/"},{"@type":"EducationalOccupationalCredential","credentialCategory":"certificate","name":"Certificat CE Legrand 4000 A","url":"https:\/\/devpan.com\/fr\/entreprise\/certifications\/"},{"@type":"EducationalOccupationalCredential","credentialCategory":"certificate","name":"Certificat CE ABB 4000 A","url":"https:\/\/devpan.com\/fr\/entreprise\/certifications\/"},{"@type":"EducationalOccupationalCredential","credentialCategory":"certificate","name":"Certificat d\u2019essai sismique","url":"https:\/\/devpan.com\/fr\/entreprise\/certifications\/"},{"@type":"EducationalOccupationalCredential","credentialCategory":"certificate","name":"Certificat GOST","url":"https:\/\/devpan.com\/fr\/entreprise\/certifications\/"},{"@type":"EducationalOccupationalCredential","credentialCategory":"certificate","name":"Certificat ISO 9001 \u2013 syst\u00e8me de management de la qualit\u00e9","url":"https:\/\/devpan.com\/fr\/entreprise\/certifications\/"}],"knowsAbout":["IEC 61439","Low-voltage switchgear and controlgear assemblies","Main distribution boards","Motor control centres (MCC)","Power factor correction panels","Medium-voltage switchgear","Ring main units (RMU)","Busbar systems","Industrial automation and SCADA"]},{"@type":"Person","@id":"https:\/\/devpan.com\/fr\/#\/schema\/person\/3c5324d50ad0d58be167633ef55c943c","name":"admin","image":{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/secure.gravatar.com\/avatar\/8caee90c0299048f405dbeffa66ec71ea4c1d3c3ed137bda9fbdd550b6c3983e?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/8caee90c0299048f405dbeffa66ec71ea4c1d3c3ed137bda9fbdd550b6c3983e?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/8caee90c0299048f405dbeffa66ec71ea4c1d3c3ed137bda9fbdd550b6c3983e?s=96&d=mm&r=g","caption":"admin"},"sameAs":["https:\/\/devpan.com"]}]}},"_links":{"self":[{"href":"https:\/\/devpan.com\/fr\/wp-json\/wp\/v2\/posts\/12119","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/devpan.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/devpan.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/devpan.com\/fr\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/devpan.com\/fr\/wp-json\/wp\/v2\/comments?post=12119"}],"version-history":[{"count":1,"href":"https:\/\/devpan.com\/fr\/wp-json\/wp\/v2\/posts\/12119\/revisions"}],"predecessor-version":[{"id":15086,"href":"https:\/\/devpan.com\/fr\/wp-json\/wp\/v2\/posts\/12119\/revisions\/15086"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/devpan.com\/fr\/wp-json\/wp\/v2\/media\/12174"}],"wp:attachment":[{"href":"https:\/\/devpan.com\/fr\/wp-json\/wp\/v2\/media?parent=12119"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/devpan.com\/fr\/wp-json\/wp\/v2\/categories?post=12119"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/devpan.com\/fr\/wp-json\/wp\/v2\/tags?post=12119"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}