We group our references into three main segments. Each one reflects not only the building type but also the engineering problem the switchboard has to solve: continuity of supply and accurate metering in residential projects, operational continuity and regulatory compliance in commercial and public buildings, and motor loads and harsh operating conditions in industry.
RESIDENTIAL AND MIXED-USE
Residential Projects
In residential and mixed-use campuses, the priorities are accurate metering of each unit, safe management of common-area loads and confining any fault to a single zone. In these projects, main distribution boards, building and floor sub-distribution boards, generator changeover panels and power factor correction systems are designed together.
Shopping malls, hotels, hospitals and clinics, university and school campuses, exhibition centers, sports facilities and public buildings have high occupancy and high downtime costs. Selectivity, redundant supply, fire-scenario segregation and remote monitoring are therefore at the heart of the design.
In factories, power and water treatment plants, ports, hangars, data centers, cultural buildings such as opera houses and museums, and embassies and consulates, motor loads, high short-circuit withstand and an IP rating suited to site conditions come to the fore. In these projects, motor control centers, high-withstand main distribution boards and automation solutions that ensure process continuity are handled together.
DevPanel main distribution boards, DevControl motor control centers, DevComp power factor correction panels, DevBox sub-distribution boards and DevPower lighting and power panels.
Medium voltage switchgear
Dev24/36 modular metal-enclosed switchgear and DevRMU gas-insulated ring main units.
Engineering and project management
Single-line diagram and layout design, equipment selection, manufacturing follow-up and site coordination; project design and project management.
Automation and energy monitoring
Energy consumption across the facility is made visible with SCADA-based monitoring, remote metering, alarm management and reporting.
BUILDING TYPES
Building types we have experience with
ResidenceResidential compoundMixed useShopping MallHotelOfficeUniversityExhibition and congress centerTown hallData CenterFactoryLogistics centerSports complexHangarAirport terminalEmbassyHospitalSchool campusPower plantWater treatment plantPortRailway StationTechnology campusDefense industry facilityBankClinicIndoor sports hallOpera houseMuseumConsulate
Request references for your project
Send us your technical specification and we will include detailed references for projects of similar size and use with our quotation.
Get in touch
A reference list is more than a count of panels delivered: it shows our ability to handle different load profiles and regulations with the same discipline.
FAQ
Frequently Asked Questions About Our References
For which types of projects do you produce electrical panels?
We manufacture low voltage panels and medium voltage switchgear for residential and mixed-use campuses, shopping malls, hotels, hospitals and clinics, office buildings, university and school campuses, fair and congress centers, public buildings, data centers, logistics centers, factories, power plants, water treatment plants, ports, airport terminals, sports facilities, cultural buildings such as opera houses and museums, embassy and consulate buildings and special structures such as hangars.
Do you work on projects abroad?
Yes. In addition to Turkey, our reference list includes projects in Azerbaijan, Kazakhstan, Uzbekistan, Turkmenistan, Tajikistan, Georgia, Iraq, Syria, Mauritania, Senegal, Nigeria and South Sudan. For export projects, panels are split into shipping sections and delivered with site assembly documents.
Which product groups are used in reference projects?
Depending on project needs: DevPanel main distribution boards, DevControl motor control centers, DevComp power factor correction panels, DevBox sub-distribution boards and DevPower panels on the low voltage side, and Dev24/36 and DevRMU switchgear on the medium voltage side.
Do you design custom solutions for each project?
All our panels are designed project by project. The single-line diagram, load schedule, short-circuit calculation, IP rating and layout constraints are reviewed at the quotation stage; instead of a standard catalog panel, we build a solution verified against your specification.
According to which standards are the panels verified?
Low voltage panels are built to TS EN 61439-1/-2, medium voltage switchgear to IEC 62271-200 and IP ratings to TS EN 60529. Designs are based on type test reports, and every panel undergoes routine tests. You can review our documents on the Certificates page.
Do you share a detailed reference list?
Beyond this selection, we can share a more comprehensive reference list for your segment on request. Just contact us via the contact page.
RELATED PAGES
See more
Products – low voltage panels and medium voltage switchgear
Engineering – project design, project management and automation
Certifications – type test, CE, seismic and ISO certificates
Quality Approach – our approach to verification and traceability
About Us – our production capability and organization
Contact – quotation requests and specification review